Pictures may not be actual SKU

Digital Dialysate - Handheld Meters

Product info
Description
Myron L's DI Dialysate Instruments - Conductivity - Resistivity - TDS - pH - ORP - Temp
Configuration
Base Model
Series
HH | Handheld Meters & Pen Testers
Model
DI | Dialysate Instruments - Digital
Availability Call to confirm
Select model  or  search within  this product range
Models are:  In Stock
Ships from PA - GA - FL - OH - OR
Typically ships within [ 0 to 2 ] days
24/7 Sales & Support 484-544-0506
$1,890.00
$1,606.50 Starting at 15 %
Headline

Digital Dialysate Meters

The DIGITAL DIALYSATE METER is specifically designed to test both acetate and bicarbonate dialysate quality. Measure Conductivity, pH and Temperature to ensure proper mixing during dialysate preparation and as a final check of dialysate quality before hemodialysis treatment. There are no strips or reagents that expire or subjective interpretation of results. Internal sensors require the user to place the sample in the instrument, preventing contamination of dialysate by the measurement device.

Features & Benefits
Features & Benefits
  • Tests up to seven aqueous parameters (depending on model): Conductivity, Resistivity, TDS, pH, ORP, Free Chlorine Equivalent (FCE TM) and Temperature
  • Factory programmed solution models for dialysate and hemodialysis water quality testing
  • Keypad calibratable
  • Autoranging conductivity/TDS/resistivity
  • Conductivity/TDS/Resistivity accuracy of ±1% of reading vs. full scale
  • pH accuracy of ±.01 pH units
  • Extremely accurate 4 electrode conductivity cell technology
  • Integrated cell cup and sensors prevents contamination
  • Full four-digit LCD display with superior resolution
  • Memory storage for 100 readings with date & time stamp
  • Real time clock
Additional Notes
Specifications:
Specs Value
Display 4 Digit LCD
Dimensions (LxWxH): 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 in.
Weight: 352 g/12.4 oz.
Case Material: VALOX®*
Cond/Res/TDS Cell Material: VALOX®*
Cond/TDS Electrodes (4): 316 Stainless Steel
Cond/Res/TDS Cell Capacity: 5 mL/0.2 oz.
pH/ORP Sensor Well Capacity: 1.2 mL/0.04 oz. (D-6)
Power: 9V Alkaline Battery
Battery Life: >100 Hours/5000 Readings
Operating/Storage Temperature: 0-55°C/32-132°F
Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet)
Chemical Resistance: Resistant to hydrocarbons, dilute acids and bases, detergents, and aqueous salt solutions
EMI/RFI Ratings (Conformité Européenne): EN61326-1: 2006 + Annex A: 2008 (hand-held devices), CISPR 11: 2003, IEC 61000-4-2: 2001 and, IEC 61000-4-3: 2002
Flammability: PCB: UL 94, V.0; Case: HB/1.47 or better

Parameters
Conductivity TDS Resistivity pH ORP mV/ppm Free Chlorine Temperature
Ranges 0–9999 µS/cm
10–200 mS/cm
in 5 autoranges
0–9999 ppm
10–200 ppt
in 5 autoranges
10 KΩ–30 MΩ 0–14 pH ±999 mV
0.2–9.9 ppm
(5<pH<9)
0–71°C
32–160°F
Resolution 0.01(<100 µS)
0.1(<1000 µS)
1(<10 mS)
0.01(<100 mS)
0.1(<200 mS)
0.01(<100 ppm)
0.1(<1000 ppm)
1(<10 ppt)
0.01(<100 ppt)
0.1(<200 ppt)
0.01(<100 KΩ)
0.1(<1000 KΩ)
0.1(>1 MΩ)
±0.01 pH ±1 mV
0.1 ppm
0.1°C/F
Accuracy ±1% of reading ±1% of reading ±1% of reading ±0.01 pH* ±1 mV
± 2.5% of reading ppm
±0.1°C
Auto Temperature
Compensation
0–71°C
32–160°F
0–71°C
32–160°F
0–71°C
32–160°F
0–71°C
32–160°F
Conductivity/TDS
Ratios Preprogrammed
KCl, 442**, NaCl KCI, 442**, NaCl
Alternate configurations
SKU Description List price -
MLC-D4 D-4 | Digital Dialysate Meter D4 - Conductivity - TDS - Resistivity - Temp $1,984.00
MLC-D4BD D-4BD | Digital Dialysate Meter D4 w/ Bluetooth - Conductivity - TDS - Resistivity - Temp $2,268.50
MLC-D6 D-6 | Digital Dialysate Meter D6 - Conductivity - TDS - Resistivity - Temp - pH - ORP $2,411.00
MLC-D6BD D-6BD | Digital Dialysate Meter D6 w/ Bluetooth - Conductivity - TDS - Resistivity - Temp - pH - ORP $2,695.50
Call or text: +1 (484) 544-0506

The Supplyline team is here to help!