DL76
Data Logger
The DL76 is a battery-powered data logger that can be used with any Seametrics flowmeter. It stores pulses for up to 3 years, depending on the user-selected frequency of reading. Indicator lights on the unit flash to indicate when it is functioning and when the battery is low.
Features & Benefits
Features:
- Battery-powered data logger
- 3.6 Vdc lithium battery included, 3-year battery life
- Compatible with any Seametrics flowmeter
- Uses Seametrics FlowInspector software
- Stores pulses for up to 3 years (depending on sampling interval)
- Available in meter-mount or wall-mount models
- Data retrieval by laptop computer
- Single data retrieval device serves multiple data loggers
Additional Notes
Specs | Value |
---|---|
Power | Size C 3.6 Vdc lithium battery (included) |
Battery Life | Estimated life is 3-5 years depending on usage. |
Temperature | 0˚ to 130˚ F (-18˚ to 54˚C) |
Rate Units Volume | mL, liter, gallon, Imperial gallon, cubic foot, cubic meter, million gallon |
Rate Units Time | Seconds, minutes, hours, days |
Total Units | Liter, gallon, Imperial gallon, cubic foot, cubic meter, million gallon, acre-foot, acre-inch, megaliter, thousand-gallon |
Maximum Input Frequency | 500 Hz |
Indicators | Low battery; Power |
Memory Wraparound | Selectable options (Stop or Overwrite) on 512KB Internal Memory |
Clock Accuracy | 10 minutes/month (.02%) |
Environmental | NEMA 4X, IP66 |
Data Storage Capacity | Example: If logging interval is every 480 seconds (8 min.) = 7.5 datapoints/hour = 180 datapoints/day. Therefore: for 365 days capacity is 65,700 datapoints/year. |
---|---|
Capacity | Sampling Interval |
11 days | 15 seconds |
22 days | 30 seconds |
44 days | 60 seconds |
6 months | 240 seconds |
1 year | 480 seconds |
3 years | 1450 seconds |